Home
>
Section
>
Chapter
Young, G.
Optometry and Vision Science Official Publication of the American Academy of Optometry 91(7): E167-E176
2014
ISSN/ISBN: 1538-9235 PMID: 24901489 DOI:10.1097/opx.0000000000000306Accession:054273225
Full-Text Article emailed within 0-6 h
Payments are secure & encrypted
Summary
To evaluate the effect of varying lens and ocular topography parameters on soft contact lens (SCL) fit, using a novel computer spreadsheet model. Although SCLs are worn by more than 100 million ametropes, the factors governing their fitting characteristics are poorly understood. A spreadsheet-based computer model used a novel ellipto-conical corneal model coupled with population data on corneoscleral topography obtained in a previous clinical study. The model calculated lens edge strain (circumferential elongation) as a predictor of lens tightness. The following parameters were systematically varied: corneal curvature, corneal diameter, corneal shape factor, corneoscleral junction angle, lens base curve (BC), and diameter. The ellipto-conical corneal model showed closer concordance with actual measurements of corneal sagittal height than a simple elliptical model (limits of agreement, ±0.20 vs. ±0.25 mm; p = 0.0015). For an eye with average ocular parameters wearing a typical SCL design (BC, 8.60; diameter, 14.2 mm), the model calculated an edge strain of 2.7%. For the same SCL, the tightest fit (8.5% strain) was found with the eye showing the combination of smallest, flattest, most aspheric cornea. Conversely, the loosest fitting (-2.6%) was found with the eye showing the combination of largest, steepest, least aspheric cornea. A change in BC of 0.4 mm typically resulted in changes in edge strain of less than 2.5%, whereas a change in diameter of 0.5 mm resulted in a change of less than 2%. Using the typical SCL design and average corneal model, wide variations in corneoscleral junction angle did not critically affect lens fit. More extreme combinations of SCL and ocular parameters resulted in edge strain likely to result in a tight (>6%) or loose fit (<0%). A novel ellipto-conical corneal model in conjunction with spreadsheet mathematical modeling proved to be a useful tool for attempting to understand the factors governing SCL fit.References
Yeung, K.K.; Forister, J.F.Y.; Forister, E.F.; Chung, M.Y.; Han, S.; Weissman, B.A. 2010: Compliance with soft contact lens replacement schedules and associated contact lens-related ocular complications: the UCLA Contact Lens Study Optometry 81(11): 598-607
Jami, R. Kern; Robin, L. Chalmers; Leslie Napier; Chris Hunt; Graeme Young 2011: Soft Contact Lens Wearers With CL-Related Dryness: Can Soft Contact Lens Care System Impact Symptoms and Comfortable Wearing Time? Optometry - Journal of the American Optometric Association 82(6): 349-350
Fogt, J.S.; Satiani, N.; Patton, K. 2023: Wear Experience with a daily disposable soft contact lens for astigmatism in current wearers of a reusable soft toric contact lens Journal of Contact Lens Research and Science 7(1): E1-E6
Seibel, E J.; Trilsch, W R.; Lee, D 1988: Evaluating Soft Contact Lens Quality Optometry and Vision Science 65(4): 298-307
Seibel, E.J.; Trilsch, W.R.; Lee, D. 1988: Evaluating soft contact lens quality: a manufacturer's perspective American Journal of Optometry and Physiological Optics 65(4): 298-307
Chan, V.W.Y.; Phan, C.-M.; Walther, H.; Ngo, W.; Jones, L. 2021: Effects of Temperature and Blinking on Contact Lens Dehydration of Contemporary Soft Lens Materials Using an in Vitro Blink Model Translational Vision Science and Technology 10(8): 11
Doi, K.; Nakayama, H.; Nakajima, T.; Sakai, N. 2003: Ophthalmic compositions for soft contact lens, method of enhancing wettability of soft contact lens, and method of inhibiting terpenoid adsorption Official Gazette of the United States Patent and Trademark Office Patents 1269(2)
Imamura, Y.; Chandra, J.; Mukherjee, P.K.; Lattif, A.A.; Szczotka-Flynn, L.B.; Pearlman, E.; Lass, J.H.; O'Donnell, K.; Ghannoum, M.A. 2008: Fusarium and Candida albicans biofilms on soft contact lenses: model development, influence of lens type, and susceptibility to lens care solutions Antimicrobial Agents and ChemoTherapy 52(1): 171-182
Clark, A.; Siegel, D.J.; Cedrone, R.; Davis, R.; Eiden, B.; Klein, S.; Lutz, S.; Forsythe, G. 2010: Clinical Evaluation of Cooper Vision's Biofinity Toric Daily Soft Contact Lens Versus Vistakon's Acuvue Oasys for Astigmatism Daily Wear Soft Contact Lens Optometry - Journal of the American Optometric Association 81(6): 273
Murphy, D.A.; Samples, J.S.; Zepeda, E.M.; Riaz, K.M. 2021: Progression from Soft Lens to Piggyback Soft-Scleral Contact Lens System to Facilitate Scleral Lens use in a Pediatric Patient Eye and Contact Lens 47(7): 426-428
López-De La Rosa, A.; Arroyo-Del Arroyo, C.; Cañadas, P.; López-Miguel, A.; Calonge, M.; Enríquez-De-Salamanca, A.; González-García, Mía.J. 2018: Are Contact Lens Discomfort or Soft Contact Lens Material Properties Associated with Alterations in the Corneal Sub-Basal Nerve Plexus? Current Eye Research 43(4): 487-492
Irkeç, M.T.; Orhan, M.; Erdener, U. 1999: Role of tear inflammatory mediators in contact lens-associated giant papillary conjunctivitis in soft contact lens wearers Ocular Immunology and Inflammation 7(1): 35-38
Szczotka-Flynn, L.B.; Imamura, Y.; Chandra, J.; Yu, C.; Mukherjee, P.K.; Pearlman, E.; Ghannoum, M.A. 2009: Increased resistance of contact lens-related bacterial biofilms to antimicrobial activity of soft contact lens care solutions Cornea 28(8): 918-926
Sengor, T.; Aydin Kurna, S.; Ozbay, N.; Ertek, S.; Aki, S.; Altun, A. 2012: Contact lens-related dry eye and ocular surface changes with mapping technique in long-term soft silicone hydrogel contact lens wearers European Journal of Ophthalmology 22(Suppl 7): S17-S23
Yung, M.S.; Boost, M.; Cho, P.; Yap, M. 2007: Microbial contamination of contact lenses and lens care accessories of soft contact lens wearers (university students) in Hong Kong Ophthalmic and Physiological Optics: the Journal of the British College of Ophthalmic Opticians 27(1): 11-21
Chalmers, R.L.; Wagner, H.; Mitchell, G.Lynn.; Lam, D.Y.; Kinoshita, B.T.; Jansen, M.E.; Richdale, K.; Sorbara, L.; McMahon, T.T. 2011: Age and other risk factors for corneal infiltrative and inflammatory events in young soft contact lens wearers from the Contact Lens Assessment in Youth (CLAY) study Investigative Ophthalmology and Visual Science 52(9): 6690-6696
Veliksar, T. A.; Gaidamaka, T.B.; Drozhzhina, G.I.; Molodaia, A.L.; Ivanova, O.N.; Dolenko, L.V.; ; , 2020: Comparing the microflora of the conjunctiva and contact lens in therapeutic soft contact lens wearers Oftalmologicheskii Zhurnal 89(6): 8-13
Xiao, K.; Song, H.; Chen, Z.; Long, Q. 2023: Conjunctival microbiome changes in soft contact lens users and contact lens discomfort patients Biomarkers: Biochemical Indicators of Exposure Response and Susceptibility to Chemicals 28(6): 531-537
Ando, I.; Kawaguchi, T.; Ichinohe, S.; Yamazaki, T. 1998: Water-absorptive soft contact lens material and contact lens made thereof Official Gazette of the United States Patent and Trademark Office Patents 1212(4): 3837
Mamada, N.; Kuwabara, H. 1968: Theoretical and clinical studies on soft contact lens. 3. Flush fitting of gel contact lens Kaiin Dayori. Membership News . Nippon Kontakuto Renzu Gakkai 10(3): 31-34